Eutech CON 2700

  • Product Code: Eutech CON 2700

Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once. :: Choose auto-calibration with prese..

Tags: Eutech CON 2700

Conductivity Range 0.050 µS to 500.0 mS Resolution 0.01 / 0.1 µS ; 0.001 / 0.01 / 0.1 mS Accuracy ±1 % full scale Cal. Points Up to 5 Cell Constant 0.010 to 10.000 TDS Range (Depending On TDS Factor) 0.050 ppm to 500 ppt (@ TDS factor 1.00) Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Accuracy ±1 % full scale Cal. Points Up to 5 Salinity Range 0.0 to 80.0 ppt Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Accuracy ±1 % full scale Resistivity Range 2.000 Ohm to 20.0 MOhm Resolution 0.01 / 0.1 Ohm ; 0.001 / 0.1 kOhm ; 0.01 MOhm Accuracy ±1 % full scale Temperature Range (Meter) 0.0 to 100.0 ºC / 32.0 to 212.0 ºF Resolution 0.1 ºC / 0.1 ºF Accuracy ±0.3 ºC / ±0.5 ºF Coefficient (Per ºC) Linear & pure ; 0.000 to 10.000 % Normalization 15.0 to 30.0 ºC / 59.0 to 86.0 ºF Compensation ATC / MTC Power Requirements 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)
ECCON270043S Eutech CON 2700 Meter With 4-Cell Conductivity/ATC Probe (CONSEN9201D)
Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ±1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once. :: Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy :: Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button :: Quick, easy electrode diagnosis with the effective cell constants display :: Replatinization in 5 minutes with the built-in replanitization circuit :: Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance :: Bi-directional RS232 for easy data transfer to computer :: Cal-due alarm – no more out-dated calibrations! :: Auto-logging function for convenient continuous monitoring :: Limit alarm alerts when reading falls out of range :: Password protection for setup and calibration Applications • Environmental studies • Chemical laboratories • Quality assurance testing • Food science • Ecological studies • Education institution
Special Ofers For Subscribers

Ten Percent Member Discount